We Proudly Accept:
|

Japanese, Taiwanese and Korean Replacement Parts
|
HPQ-T
PIPE MOUNTED, SELF-CONTAINED LIQUID SENSOR
The HPQ-T sensor is designed specifically for liquid level
detection by non-contact methods in clear or very translucent pipes.
The sensor is mounted on a pipe that is between
3 to 7mm or 8 to 13mm in diameter and features an infrared light
beam that becomes refracted and undetectable by the receiver when
the liquid is present. The device runs on 10-28 VDC, has a response
time of 2 msec max, has Light Operate/ Dark Operate Selectable output
functioning, and has a 100 mA NPN or PNP output. There is minimal
malfunction when air bubbles or water droplets are present. The
indicator light is easy to view even when the sensors are gang mounted
as all the controls and adjustments are located on the back side.
|
|
Features
and Benefits
- Small compact size and non-invasive sensing make
installation and height adjustment easy
- Many products to select from - provides flexibility
to user based on concerns
- Thru scan principle where liquid refracts light
beam -insures reliable detection
- Infrared beam can help penetrate slurries and
other solids with similar detection effect as water/liquid. This
can be used in mixing sections of the process.
- Light operate / dark operate selector switch
provides output flexibility.
- Indicator lamp is easy to view even when sensors
are gang mounted
Usage Recommendation
The standard gain
setting versions work with most liquids. The 25% gain reduction
should be used when large quantities of bubbles are present or where
mixing in chambers requires the sensor to be able to detect water/fluid,
solids, and mixture of solids/fluids equally. We recommend that
the prospective user evaluate their chemical combinations and mixing
situations to determine which sensor works best before finalizing
the specification for use
|
| Catalog
Listings |
| HPQ-T1 |
NPN Output, 8-13mm
O.D. pipe use, standard gain setting for most applications. |
| HPQ-T2 |
PNP Output, 8-13mm
O.D. pipe use, standard gain setting for most applications. |
| HPQ-T1-004 |
NPN Output, 3-7mmO.D.
pipe use, standard gain setting. |
| HPQ-T2-005 |
PNP Output, 3-7mmO.D.
pipe use, standard gain setting. |
| HPQ-T1-008 |
NPN Output, 8-13mm
O.D. pipe use, 25% gain reduction from standard. |
| HPQ-T2-009 |
PNP Output, 8-13mm
O.D. pipe use, 25% gain reduction from standard. |
| Specifications |
| NPN Models
PNP Models |
| Scanning Type |
Through Scan |
| Supply Voltage |
10 to 28 V DC (ripple 10% max.) |
| Current consumption |
25 mA max. |
| Usable Pipe |
see catalog listing chart |
| Standard detecting object |
Water
Note 1 |
| Repetitive detecting agency |
1 mm max. |
| Operating Mode |
Light-operated/dark-operated selectable
(with L-On/D-On selector)
Detecting object: dark, Non-detecting object: light |
| Output |
Open collector of NPN transistor |
Open collector of PNP transistor |
| Response time |
2ms max. |
| Light Source |
Infrared LED |
| Indicator |
Red "on" with detection |
| Ambient Light |
Incandescent 1000 lx max. |
| Operating temperature |
-10 ~ +55°C |
| Storage temperature |
-25 ~ +70°C |
| Humidity |
35~85% RH (without condensation) |
| Insulation resistance |
20 M min. (at 500 V DC) |
| Dielectric strength |
1000 V A 50/60 Hz 1 minute |
| Vibration |
10~55 Hz, 15 mm double amplitude,
2 hours in each direction of X,Y,Z |
| Shock |
500 m/s2 (approx. 50g)
3 times in each direction of X,Y,Z |
| Sealing |
IP50 (IEC standard) |
| Mass |
Approx. 25g |
| Protection |
False pulse protection (20ms type),
reverse polarity protection |
| Approvals-CE to be completed by end 2002 |


RAS Machine Tool Technologies, Inc.
30 Business Technology Drive · P.O. Box 652 · Belchertown, MA 01007
· sales@rasmachinetool.com
Website Development and Maintenance by GetSet