New Technology!
High-Pressure Super Unit
Inverter Controlled Hydraulic Unit

Daikin original High-efficiency IPM motor drive system is integrated with combination control tandem pump to achieve enormous energy-savings and highly sophisticated functions.

Features

  • Easy setting of Multi-stage Pressure/Flow control
    4 patterns of Pressure/Flow can be set on touch panel and selected with input signal. Shock-less control at the pattern switching is also available.
  • 50% energy savings (at 20.6 MPa Dead-Head pressure) saving your running cost.
    Energy saving system was developed by fusing air-conditioning motor/inverter technology with oil-hydraulic combination control tandem-pump.
    Enormous energy-savings can be achieved by adopting a high-efficiency motor even in the general industrial machinery field where the ratio of not only stand-by condition by also actuator operation is high.
  • Low Noise 60dB(A) (at 20.6 MPa Dead-Head pressure 70 dB(A) or lower even in the full-operation area
    Low pulsation and low noise according tandem phase-difference pumps.
  • Wide production range
    15.7 MPa, 40L/min to 20.6 MPa, up to 60 L/min produced in series.
    And we flexibly arrange options according to customer requirements.
Type
SUT06D40L16-10
SUT10D40L16-10
SUT06D60L21-10
SUT10D60L21-10
Max. flow rate (theoretical value) (L/min)
41.0
61.1
Max. operated pressure (MPa)
15.7
20.6
Tank capacities (L)
60
100
60
100
Pressure adjustment range (MPa)
1.5~15.7
1.5~20.6
Discharge rate adjustment range (L/min)
5.4~41.0
8.7~61.1
Power Supply
Motor pump
200/200/220V, 50/60/60Hz
AC fan motor
200/200/220V, 50/60/60Hz (supplied from controller)
External input signal
3 points, photo-coupler insulation, DC24V (Max. 27V), 5mA
External output signal
Alarm output
2 points, (1C contact), dry contact, contact capacity: DC30V 0.5A (resistance load)
Warning output
1 point each, photo-coupler insulation, open-collector output DC 24V, 30 mA or lower
Pressure switch output
Working Oil
Mineral oil based hydraulic oil/wear-resistant hydraulic oil
Viscosity grade:ISO VG32~68
Viscosity range: 15~400 mm2/s (20~200 mm2/s recommended)
Degree of contamination: within NAS Class 9
Tank oil Temperature
0~60C (15~50C recommended)
Ambient temperature
0~35C
Ambient Humidity
20~85%RH
Location
Indoors (be sure to fix with bolts, etc.)
Weight (kg)
95
110
100
115
Optional Items Max. output characteristics

  • Selecting four patterns of Pressure/Flow characteristics preset to the controller by input signal from the main machine side can easily achieve multistage pressure/flow rate control.
  • Shock-less control is enabled by adjusting the buildup/break time of switching Pressure/Flow characteristics.
  • According pump control except conventional valve operation, the system can be simplified and the cost can be reduced for such application high-speed and low-speed of presses, etc. those are switching or multi-stage pressure control is carried out.